A cleanroom workshop, independently verified.
We built the cleanroom for one job: bonding. And we split it in two. Dark technical fabrics shed lint; a single dark fiber landing on a light-coloured bonding bed is a visible defect that no amount of downstream inspection recovers. So light-colour and dark-colour bonding run in physically separated zones. The third-party test confirms the separation works — the light-colour zone measured 4,236 particles per cubic metre against 26,475 in the dark-colour zone, six times cleaner, by design rather than by luck.
Six zones, measured — not claimed.
In August 2026 an accredited third-party laboratory tested every zone of the facility against GB 50073-2013. All six passed. Read the two bonding rows together: the light-colour zone sits six times cleaner than the dark-colour zone, and 831 times under the Class 8 particle limit. That gap is the whole point of separating them.
| Zone | Particles ≥0.5 micron · pc/m³ | Temp | RH | Air changes | vs Class 8 limit | Microbial |
|---|---|---|---|---|---|---|
| Corridor | 2,471 | 25.3°C | 64.1% | 12 /h | 1,424× | None detected |
| Bonding zone 2 — light-colour | 4,236 | 25.3°C | 64.3% | 11 /h | 831× | 10 cfu/m³ airborne |
| Inspection hall — 2 sewing floors merged | 7,060 | 25.5°C | 64.7% | 10 /h | 499× | None detected |
| Bonding zone 1 — dark-colour | 26,475 | 25.2°C | 64.3% | 10 /h | 133× | None detected |
| Laser room 1 | 141,553 | 25.5°C | 63.8% | 15 /h | 25× | 5 cfu/m³ airborne |
| Laser room 2 | 619,868 | 25.3°C | 63.5% | 14 /h | 5.7× | None detected |
Every step on the floor, tracked digitally.
Fabric inspection. Cutting. Bonding. Sewing. Each handoff logged into a single production record. We're building this internal platform in-house, using Feishu's cloud spreadsheets as the structured backbone. Within two years, an AI agent should handle the production scheduling itself.